Back to home
Technology · MOD-01

Sensor Grid Tile

The Sensor Grid Tile is the under-vehicle detection cell. One cell sits beneath each parked vehicle on an instrumented deck. The cell observes the bay continuously — there is no scheduled scan, no rotating element, and no contact with the vehicle, the battery, or the OEM warranty envelope.

What it senses

  • Infrared thermal field across the underbody at a resolution sufficient to resolve a per-cell hot-spot before it propagates.
  • Electrochemical gas detection tuned for the specific volatile signatures of lithium-ion electrolyte venting (including hydrogen and characteristic VOC families).
  • Vehicle presence and absence, so the system distinguishes an empty bay from a parked vehicle without operator input.

Why multi-modal

Single-modality detection — thermal-only or gas-only — is fragile under the dilution conditions of an enclosed cargo deck. Multi-modal fusion is what allows a tier-2 alert to be raised with high confidence minutes ahead of any visible smoke. Modality fusion runs on the segment master, not in the cell, so the cell remains low-power and long-MTBF.

Environmental envelope

Enclosure rating
IP66 / IP68 marine-grade
Operating temperature
−25 °C to +70 °C
Vibration / shock
Designed to IEC 60945 maritime equipment standard
Power budget
Sub-watt per cell, bus-powered
Update rate
50 Hz nominal
MTBF target
> 200,000 hours (bench)
Note
Performance figures are bench-rig values from the current engineering revision. Fleet-deployment values will be re-stated against type-approval test reports as each programme completes.

Installation

Cells install non-invasively — no drilling of the deck, no modification to the vehicle, no impact to the OEM warranty. A single deck installs alongside the berth in approximately three working days, without drydock. Installation methodology is subject to a pending Indian patent; specifics are documented for pilot customers under NDA.

What we do not publish here

Mechanical mounting geometry, sensor coordinates relative to deck features, and the internal modality-fusion thresholds are IP-sensitive and patent-pending. These are available to pilot counterparties under signed NDA.

Note
Email rorosafetech@gmail.com or book a 30-minute call. We typically reply within one business day.
Contact
rorosafetech@gmail.com
Daite Software Pvt Ltd · 1/734b, Padianallur, Chennai - 600052, Tamil Nadu, India